PREREQUISITES: GRIDSMART Processors MUST first be updated to 22.1.3 or later.


CRITICAL NOTE ABOUT THE UPDATE: This update will take less than 10 minutes to complete. It includes both low-level firmware updates as well as security updates to the underlying operating system. Upon reboot, it may take several minutes for the system to start up while the operating system updates are applied, with both the STATUS and CAMSTAT LEDs flashing during this time.


DO NOT DISRUPT THE SYSTEM DURING THIS TIME.


When the update is complete, it will be indicated in two ways:

  • The phase LEDs on the front of the processor will all turn green.
  • The Web App displays a progress bar during the update that will show that the update has completed and the system is rebooting.

NEW: Adds support for the FE3, AC3 and SC3.

FIX: Fixes an issue where cameras that rebooted more than 5 times since Processor startup appeared as offline in the Web App but online in the Desktop App. Now, any camera that reboots more than 5 times in a 24 hour period will stay offline until midnight. If any cameras are offline at midnight, the processor will be rebooted in an attempt to recover system operations.

FIX: Fixes a bug on the GS3 which caused vehicles to be undercounted. Vehicle detection accuracy was not affected by this bug.

FIX: Fixes a bug that affected the GS2 where an older version of firmware was deployed as part of recent updates. This restores the fix for a previous issue where detectors calls were incorrectly mapped for ITS and ATC cabinets. GRIDSMART Detector inputs 1-24, SIU Inputs 6-29, have been restored on all 5 input SIUs 9-13.